126KV Outdoor high-voltage SF6 ceramic column circuit breaker is a high-voltage sulfur hexafluoride device used in outdoor electrical systems operating at 126kV. It is designed to manage and safeguard power transmission and transformation networks. This breaker can serve as a switch and disconnection unit when needed. The breaker's innovative arc extinguishing technique involves thermal expansion and auxiliary blowing, and it incorporates a CTB-1 operating mechanism. It complies with the GB1984-2003 standard for AC High Voltage Circuit Breakers and ful specifications of the IEC62271-100:2001 standard for High Voltage Switchgear and Control Equipment Part 100: High Voltage AC Circuit Breakers established by the International Electrotechnical Commission.
consulte Mais informaçãoEnviar consultaThe 72.5KV Outdoor high-voltage SF6 ceramic column circuit breaker is designed for controlling and protecting 72.5KV transmission and transformation systems. It operates on a three-phase AC 50HZ outdoor high-voltage switchgear and can function and opener group. By utilizing the intelligent arc extinguishing principle of "thermal expansion+auxiliary blowing" and equipped with a CTB-1 operating mechanism, this circuit breaker meets the standards of GB1984-2003 and International Electrotechnical Commission standard IEC62271-100:2001 for High Voltage AC Circuit Breakers.
consulte Mais informaçãoEnviar consultaO interruptor de isolamento de dois postes de interrupção central de 36KV é fabricado em porcelana de alta resistência, o que aumenta a estabilidade, confiabilidade e densidade de resistência do produto. Esta formulação de material minimiza a variação de resistência e aumenta a resistência à tração do produto. O layout estrutural inclui uma margem de resistência significativa, garantindo a estabilidade operacional e confiabilidade do produto.
consulte Mais informaçãoEnviar consultaThe 12KV 1250AMP Vertical break two post isolating switch is specifically designed for use in 10(12,15,24)KV high voltage transmission and distribution lines. These switches serve the purpose of disconnecting and connecting single-phase or three-phase circuits without load and voltage. They are particularly engineered for single-phase application within a three-phase circuit system and are characterized by a simple and cost-effective design, ensuring ease of operation and maintenance. The switches are available in a range of rated current options, including 200400,600,630,800, and 1000,1250 amperes, providing the flexibility to select the most suitable option based on specific requirements. They are comprised of a base, pillar insulator, conductive part, and mechanism part.
consulte Mais informaçãoEnviar consultaThe 11KV 2000amp Vertical break two post isolating switch is a composite-structured 12KV switch designed for outdoor line networks. Equipped with a CS-type operating mechanism, it effectively prevents incorrect operations, such as interlocking with live conductors and composite flash-locks. This negates the necessity for an additional earthline, providing a convenient and efficient solution. Furthermore, the pollution-proof isolating switch is particularly well-suited for use in heavily contaminated areas, effectively addressing shed pollution during operation and ensuring a clean and safe working environment.
consulte Mais informaçãoEnviar consulta145KV 3150A Earthing switch,The neutral point serves various functions, contributing to distinct technical characteristics and operational requirements. The BJ-type transformer neutral point gap grounding protection device plays a crucial role in preserving operational reliability, equipment insulation, and protective measures to ensure consistent performance.
consulte Mais informaçãoEnviar consulta126KV 1250A Neutral point disconneetor is specifically engineered for application in high-voltage transmission lines operating under no-load conditions. Its primary function is to provide electrical isolation during the maintenance of circuit breakers and other associated equipment, thereby ensuring compliance with insulation distance requirements and enhancing overall operational safety.
consulte Mais informaçãoEnviar consultaThe The GW8 series neutral point disconnecting switch is an outdoor device designed for use with AC 50Hz and 60Hz. It is intended to connect the neutral point of a transformer under no load conditions. The switch can be easily operated using either the CJ motor operating mechanism or the CS8 manual operating mechanism. Comprising a monopole and an operating mechanism, the GW8 series ensures smooth and hassle-free operation. The monopole includes a base, post-insulator, conductive arm, contact, and other components. The operating mechanism, whether it's the CJ motor operating mechanism or the CS8 manual operating mechanism, is crucial to the disconnecting switch process. It drives the conductive arm through the connecting rod, enabling the opening and closing of the disconnecting switch. is an outdoor device designed for use with AC 50Hz and 60Hz. It is intended to connect the neutral point of a transformer under no load conditions. The switch can be easily operated using either the CJ motor operating mechanism or the CS8 manual operating mechanism. Comprising a monopole and an operating mechanism, the GW8 series ensures smooth and hassle-free operation. The monopole includes a base, post-insulator, conductive arm, contact, and other components. The operating mechanism, whether it's the CJ motor operating mechanism or the CS8 manual operating mechanism, is crucial to the disconnecting switch process. It drives the conductive arm through the connecting rod, enabling the opening and closing of the disconnecting switch.